7.
TECHNICAL DATA
Measured quantities
Relative humidity
Humidity sensor
Working range
Accuracy incl. hysteresis and nonlinearity with
- special calibration against certified standards
- standard calibration
Output signal
Response time with filter at 20°C
Temperature
Temperature sensor element
Working range
General Data
Supply voltage
Load resistor for 4 - 20 mA output
Current consumption
Working temperature range electronics
Storage temperature range
Electrical connection
Sensor protection
Electromagnetic compatibility
1) max. power dissipation 1mW
Definitions:
•
Error
possible cause
⇒
Measures / Help
•
Display shows incorrect values
Error during re-adjustment of the transmitter
⇒
Reset to factory calibration and repeat the calibration routine
Filter soiled
⇒
Replace filter
Sensor defective
⇒
Replace sensor
•
Long response time
Filter soiled
⇒
Replace filter
Incorrect filter type
⇒
Filter type should match the application
•
Transmitter failure
no supply voltage
⇒
Check wiring and supply voltage
•
High humidity values
Dew (condensation) in sensor probe head
⇒
Dry probe head and check the sensor probe mounting type
Incorrect filter type
⇒
Filter type should match the application
/ t
(68°F)
90
1)
HC1000-400
0...100% RH
±1% (0...90% RH)
±2% (0...90% RH)
Traceable to intern. standards, administrated by NIST, PTB, BEV...
4 - 20mA (3-wire)
< 15 sec.
Pt100 resp. Pt1000 (class A, DIN EN 60751) see Ordering Guide
/
-50...180°C
up to 200°C
(-58...356°F)
10 - 35V DC or 10 - 28V AC
10 - 35V DC
R
<
L
10 - 28V AC
R
< 350 Ω
L
for DC supply < 32mA
-40...60°C
(-40...140°F)
-40...60°C
(-40...140°F)
pluggable screw terminals up to max. 1.5mm²
stainless steel grid filter
Designed for installment in and with other equipment (OEM)
Measurements according to EN61000-4-3 and EN61000-4-6
FCC Part15 ClassB
13
±2% (90...100% RH)
±3% (90...100% RH)
short term
(392°F)
[Ω] (max. 350 Ω)
U
- 5V
v
0.02 A
for AC supply < 60mA
(AWG 16)
ICES-003 ClassB
eff