Herunterladen Diese Seite drucken

GYS GYSPRESS 10T PUSH PULL Bedienungsanleitung Seite 11

Werbung

During maintenance, the compressed air supply must be disconnected.
TROUBLESHOOTING
The chart below indicates the issues that can be observed during the use of the product. If the problem observed
does not appear in the table below, stop using the product and call immediately your distributor to seek support.
SYMPTOMS
The riveting machine does not work.
The rivet is not in place.
Air, leak.
18
GYSPRESS
IOT
PUSH
POSSIBLE
CAUSES
Air is not connected.
Air pressure too low.
The air pressure is not adjusted
correctly.
The potentiometer
is set at the mini-
mum speed.
Mandrel or matrix faulty
Presence of glue on the mandrel or
inside
the matrix.
The pressure is not enough
Rivet length incorrect.
Faulty pipe.
Faulty coupling.
Faulty seals.
PULL
REMEDIES
Connect the air pressure.
Check air pressure supply.
Adjust air pressure between 2 and 8
bar.
Adjust the speed laying.
Replace the mandrel or the matrix.
Clean the glue
Air pressure is too low or not well-
ajdusted.
Follow
manufacturer
Change the pipe.
Change the coupling.
Repair by the manufacturer.
EN
instructions.

Werbung

loading