Herunterladen Diese Seite drucken

Geutebruck TopLine BC Serie Installationsanleitung Seite 70

Ip boxkamera

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation Guide
(Pin 4, 6, 8 description continued from the previous page.)
For any I/O port set as an output:
In the schematic drawing on page 34, I/O-0 and I/O-1 have been set to operate as
outputs. An output port employs an open collector transistor connected to ground as
shown in the schematic.
As indicated in the table below, an output port will or will not be connected to ground
via the transistor depending on the state of the port and whether the port is or is not
set to invert.
See the camera user's manual for more information about setting a port to invert.
Note: If an output port has been set to invert and you restart the camera or you
power it off and back on, the port will not invert during the camera bootup process
and will return to inverted once the bootup process is complete.
Output State
Inactive
Active
Inactive
Active
The maximum current is 100 mA and the maximum voltage is +24 VDC.
If an inductive load such as a relay is connected to an output port, a diode must be
connected in parallel with the load as shown in the schematic drawing on page 34.
Table 1: Terminal Connector Pin Assignments
32
Port Set To Invert
No
No
Yes
Yes
Output Pin Connected
to Ground
No
Yes
Yes
No