TEMPERATURE SETTING
23
DHW heating operation
The DHW heating operation's minimum setting temperature is 30 °C.
• The desired temperature can be controlled in the units of 1 °C.
- Set the desired temperature higher than the DHW tank temperature.
- DHW tank temperature is displayed on the default screen of the remote controller.
- When the desired temperature is set lower than the DHW tank temperature, warm water
doesn't come out.
- If your unit is operating in DHW heating mode and you press the [On/Off] button the DHW
heating operation will shut off.
NOTE
• In the heating operation, you can select the desired temperature in the range of 30 °C~80
°C.
• If you want to know more information, refer function on installation information section.
Quick DHW tank heating
If there is urgent DHW heating demand, Quick DHW Tank Heating mode can be used to reduce
the time to reach target DHW tank temperature by forcibly turning on DHW tank heater.
After reaching target DHW tank temperature or by user's input to stop, Quick DHW Tank Heating
mode will be finished.