CAUTION - Incorrect installation may be dangerous. To prevent operations that may result in accidents and to grant a
long life to the product read this manual and strictly obey the instructions provided.
DESCRIPTION
Electric actuator in aluminium casing with rigid spindle
linear drive.
It requires 230 Volt A.C., provided with limit switch and
overload protection.
It is supplied with a cable, 1.5 m in length, to which the
actuator is internally connected. Brackets and supports
suitable for the actuator's intended use are also provided.
WARNING: this actuator is not recommended for intensive
use.
Do not install two or more actuators on the same frame.
WARNING: When you install the operator with 300 mm
travel, you MUST equip the system with a wind detection
unit.
IMPORTANT: The power-driven gate must comply with the
Construction Materials Directive and the Machine Directive.
STANDARD EQUIPMENT
1A/1B Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . Qty 1
2 Front bracket . . . . . . . . . . . . . . . . . . . . . . . . . . Qty 1
3 Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Qty 2
4 External ring . . . . . . . . . . . . . . . . . . . . . . . . . . Qty 2
5 6 x 10 screw . . . . . . . . . . . . . . . . . . . . . . . . . . Qty 2
6 Front Þ xing joint . . . . . . . . . . . . . . . . . . . . . . . Qty 1
7 Front pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Qty 1
8 Hexagonal M6 nut + toothed washer . . . . . . . Qty 1
9 6 x 30 screw . . . . . . . . . . . . . . . . . . . . . . . . . . Qty 1
10 M6 self-locking hexagonal nut . . . . . . . . . . . . Qty 1
Dimensions and positions with standard accessories
Dimensions:
see f.3-A for actuator with MAX travel 300 mm;
f.3-B for actuator with MAX travel 180 mm.
INSTALLATION
The actuator must be installed when the window is closed.
1 Mark the centre line on the window. Fix the block to the
window using screws suitable for the material the window is
made of.
2 Fix the actuator support bracket and the fixing device to
the window so that they are in line. Their height must be
adjusted so that the actuator is perpendicular to the
window. Tighten the screws.
Ensure that the actuator reaches the limit switch triggering
positions correctly and with no obstacles.
N.B. The actuator is supplied with the limit switch in the
closing position, with the window closed.
ELECTRICAL CONNECTION
Actuator with 230 Volt A.C. + - 5%. Make the electrical
connections as indicated in the diagram f.5a or 5b.
WARNING: Check that the section of the power cable is
adequate for the actuator power requirements.
Arrange for the installation of changeover switches with mid
OFF position with "live-man" control or equivalent. The
position of the switch buttons must be outside the field of
action of the mobile window.
WARNING: The motor overload protection is an electrical
motor coil temperature control probe.
I1085002/07-2023
ISTRUZIONI - INSTRUCTIONS - INSTRUCTIONS - INSTRUCCIONES - ANLEITUNG - ИНСТРУКЦИЯ
For proper electrical protection, power the motor through
an automatic protection device with overload temperature
protection setting at 0.8 A and magnetic protection setting
at 6 A.
WARNING: If the POWER CABLE is damaged, it must be
replaced by the manufacturer, or its service agent, or a
similarly qualified person in order to avoid every hazard.
DANGER of hands being crushed! When the window is
moving, do not insert your hand between the fixed frame
and the mobile pane.
This product falls within the scope of application of
Directive 2012/19/EU on waste electrical and
electronic equipment (WEEE).
For correct disposal of electrical and electronic
equipment, batteries and accumulators, the owner
must deliver the product to special "collection centres"
provided by municipalities.The symbol of the crossed-out
wheeled bin, present on equipment label, indicates that the
product is in compliance with the standard on waste
electrical and electronic equipment. The release into the
environment and the illegal disposal of the equipment shall
be punished by law.