3. Safety information
HEATSCOPE® infrared heater must be installed and executed only by an authorized expert / professional electrician.
The relevant local building and fire safety regulations must be observed.
WARNING: The heater must not be used in small rooms inhabited by people who cannot leave the room unaided, unless constant supervision is
ensured.
1. Please check that your HEATSCOPE® radiant heater and accessories are complete and not damaged. If the housing or reflector is deformed/damaged
or the heating element is broken, do not use the HEATSCOPE® unit. Please contact the vendor or the manufacturer.
The cable must not be crushed or damaged.
If the unit or accessories show signs of defects, cracking, breakage or other damage, discontinue use and have them repaired. In this case, disconnect
the unit from the power supply, return it to the manufacturer or dispose of it. The unit should be labelled accordingly to prevent it being reconnected.
2. The HEATSCOPE® features an omnipolar „ON/OFF" switch. The unit can be controlled manually either using an IR remote control (supplied, depen-
ding on the model) or a selector switch on the unit itself (depending on the model). The unit must be connected to a residual current circuit breaker
and a fuse.
3. The unit may only be used with an approved isolating system. The heater comes as standard with a separate open-ended cable for connection
purposes.
4. When installing the HEATSCOPE® radiant heater, ensure that the lower edge of the unit is at least 180 cm from the ground and the safety clearances
from the wall and ceiling set out in this manual (see below) are maintained. Always maintain a distance from the heating surface of the HEATSCOPE® of
at least 150 cm from textiles, cloth and other easy inflammable soft materials.
5. The radiant heater must not be installed directly below a power source/socket. The sides of the unit must be at least 10 cm from the nearest power
source. Sockets/power sources must be freely accessible at all times and comply with the following specifications: 220–240 V AC ~ / 50 Hz, 16 A with 16
A fuse. No other loads may be connected to this power source.
6. The HEATSCOPE® has an IP 44 protection class rating (protected against objects >1mm and splashing water). Nevertheless, it is mandatory to install
the unit on a surface where it is well protected from any weather influences like rain and dust from above; so the HEATSCOPE has to be installed under
a roof, an overhang or in combionation with an optional available weather shield.
7. In accordance with VDE 0100, Part 701, the radiant heater may only be installed in Area 3 locations in rooms where there is high humidity (ba-
throom, spa, pool etc.). The distance to the bathtub or shower must be at least 100 cm and the distance to the pool at least 200 cm. If the HEATSCOPE®
is installed in such an environment with high humidity, the switches or other operating components must be positioned in such a way that they cannot
be touched by persons who are in direct contact with water. Bathroom heaters must not be operated with a separate automatic thermostat or timer.
When a radiant heater is installed in a bathroom, the CE standard requires that at least one heating element visibly „glows" as soon as the unit is
switched on.
8. As soon as the unit is connected to a power source and switched on using an „ON/OFF" switch or other operating component, it takes a maximum of
15-30 seconds until it reached its operating temperature.
9. CAUTION: Risk of burns!
The front screen or protective fin front gets very hot when the unit is operating.
Do not cover either part of the front or the entire front of the radiant heater. Do not touch any part of the HEATSCOPE® during operation and up to 30
minutes after switching it off.
10. For your own safety, never dry textiles or other materials using the HEATSCOPE®. Covering the radiant heater may result in a fire! Always maintain a
distance from the heating surface of the HEATSCOPE® of at least 150 cm from textiles, cloth and other easy inflammable soft materials.
11. Ensure that cables, furniture, flammable materials or other objects do not come into contact with the surface of the radiant heater and never cover
the unit. Under no circumstances should the unit be covered with insulating or similar materials.
12. Disconnect the radiant heater from the power supply before cleaning it, adjusting the angle or removing it from the wall/ceiling. If buried cables are
used, switch off the power using an omnipolar switch.
13. Be careful when operating the unit. This unit is not intended for use by persons (including children) with reduced physical, sensory or mental
abilities or lack of experience and/or knowledge, unless they are supervised by a person responsible for their safety or have received instructions as to
how to operate/use the unit.
14. The unit must never be used unattended. Children must be supervised at all times to ensure that they do not play with the unit, switch it on
unintentionally or adjust it.
15. Use only the supplied accessories or original accessories approved by the manufacturer. The power cable or other components of the HEATSCOPE®
radiant heater may only be replaced by a professional servicing company enlisted by the manufacturer.
16. Always remember to switch off the unit after use.
EN

Werbung

loading