Addressing with the addressing unit AC1144
Do not remove the addressing plug while live.
If the mounted and wired module is used with the FC-E lower part
AC5011 (with addressing socket), it can be addressed via the address-
ing cable (E70213).
If it is used with the FC-E lower part AC5003 (without addressing sock-
et) the module must first be addressed via the addressing unit AC1144
and then mounted onto the lower part.
Infrared addressing
The AS-i module also offers the option of infrared addressing with the
addressing unit AC1144.
The AS-i communication (yellow cable) must be switched off
during the infrared addressing. To do so, disconnect the master.
Supply the slaves with voltage via the AS-i power supply. Addressing is
carried out via the IR addressing cable E70211.
When the ifm AS-i power supplies SL are used the communication can
be deactivated via a plug on the power supply.
If a slave with the ID code "A" (option of extended addressing
mode) is connected to a master of the first generation (version
2.0), the parameter P3 must be 1 and the output bit D3 = 0*.
The output bit D3 must not be used.
If a slave with the ID code "A" (option of extended addressing
mode) is connected to a master of the first generation (version
2.0), an address between 1A and 31A must be assigned to this
slave.
* default setting