Assembly of cooler
The protective film should be removed (if it exists)
By using adjustable feet, make the cooler stable. Avoid gaps, prevent vibration.
Compressor group air inlet must not be prevented. This is the most important issue. Allocate your product
that it will be parallel to the ground, no aim is required. Adjustable feet and rollers must touch the base. The
distance between compressor group and wall is important. More distance, provides increasing performance.
For that reason, at least 15 cm gap is required.
After transport of the cooler, before operating it, you should wait for four hours.
The first running must be done when the cooler is empty. Loading can be done after this period.
Connection of the cooler must be checked by experienced electrician. The fuse height must be 170 cm
For fault current, electric connection must be supported with 30 mA fuse.
The cooler must be also provided with the nearest ground.
Usage for the cooler
Temperature of the cooler is calibrated for the most proper conditions. The operating temperature can be
adjusted from the digital thermostat. We advise you to keep them with default factory value. Internal
temperature of the cooler, can be adjusted +1 and +10 C degrees. Digital thermostats have default factory values,
and no need adjustment. Thermostats may have many programs within (eco mode, night mode etc.) If you have
a problem with your cooler, please contact to service. Failure codes are listed in failure section. If you get any of
these, stop the alarm of the thermostat and inform the service.
There is no a private defrost process in your cooler. Although your products prevents snowing, high humidity and
temperature may cause snowing rate. Operating time depends on snowing, which also means energy
consumption will rise. At this position, stop the working and clean the snow.
DO NOT FORGET! UNFROZEN EVAPORATOR WILL GIVE THE HIGH EFFICIENCY.
Before calling service & cleaning
Before calling service
Failure
The cooler is not working.
There is only fans noise or
There is no noise.
Internal temperature is high
Internal temperature is low
Cooling lamps are not lighting
or just one is lighting
So much liquid or on the glass
or inside of cooler
Bad smells from bottom side
Internal cleaning
Remove beverages. Wait for the internal temperature that it will be same with environment temperature. For
cleaning and maintenance use a protection glove, this will protect you from injuries. Remove the accessories.
Use a soft cotton linen with warm soap water .For drying, use cotton based linen. For first operating, wait for
two hours. Than you can reload your beverages.
External cleaning
Use a cotton base linen with warm water. Avoid water from front control panel or lighting departments. For door
gasket, just use clean water with soap.
Possible solution
Check the plug and fuse. There may not be
electric. There may be thermostat.
External temperature may be high or
thermostat adjustment may be wrong. The
distance between cooler and wall may be
poor. Extremely exposed to external wings.
Condenser fins may need to be clean.
Wrong thermostat adjustment.
Lamps may be closed. Lamps or
starter may be broken.
Water drain hole may be closed.
External humidity may be over % 65.
Water drain pan should be cleaned.
Result
It will work again, when the
temperature is proper. Plug it
properly.
Decrease the external temperature or
move the cooler where the
temperature is low. Open frontside of
the air shutter. Prevent snow.
Adjust the thermostat
Open the lamps. Request for broken
parts.
Clean the water drain hole. Keep the
cooler somewhere, where the
humidity is less.
Water drain pan should be cleaned.
7