Test
Check the following before each use:
- Is there visible damage on the device?
- Is there visible damage on the control elements?
- Are the accessories in perfect condition?
- Are all lines in perfect condition?
- Is the feed unblocked?
- Are the ventilation slots clear and clean?
Do not start up a damaged device or damaged accessories. Have them checked by the manufacturer or
its customer service or a qualified service technician.
Storage
Winter storage
1. Switch the pump
3
2. Close the shut-off valves or block the water flow to the pool's connecting hoses.
3. Uninstall the connecting lines to the pool and drain the hoses.
4. Lift the pump and drain it via the two connections.
5. Drain the filter medium. To do so, carry out steps 3 to 11 in the "Exchanging the filter medium"
section.
If you are using filter balls, wash them by hand and let them dry completely. If you are using sand,
pour the sand into a suitable container (e.g. bucket) and store this in a dry place.
6. Rinse the filter system with tap water.
7. Let the filter system dry completely.
8. Press and hold down the valve lever
9. Turn the valve lever to the "WINTER" position and let go.
The device can be stored over the winter.
1. Store the device in a dry and frost-free location (>= +5 °C) without direct sunlight.
Troubleshooting
Problem
The pressure on the manometer
exceeds 1 bar.
Air bubbles escape from the
injection nozzle.
34
off by pulling the power plug.
on the valve head
22
Possible cause
The quartz filter sand is dirty.
The filter balls are dirty.
The pump is sucking in air.
.
1
Remedy
Backflush the system (see section
"Backflushing").
Remove and wash the filter balls by hand.
Exchange the filter balls if necessary.
Check all hoses and gaskets for leaks.
Retighten the hose clamps.
Check the water level in the pool and fill
in more water if necessary until the pool
water covers the suction line connection
completely.