Connecting the lines
Prepare the following components:
- Pressure line
11
- Return, backflush and suction line (not
included in the package contents)
- Assembly materials for the lines
To connect the lines to the pump and filter vessel as
shown in illustration A at the start of this manual,
proceed as follows:
1. Route the return and suction line from the pool
to the filter system.
2. Route the backflush line from the duct
connection to the filter system.
Observe the markings right at the line
connections of the valve head.
The lines are connected.
Bleeding and checking the filter system
1. Press and hold down the valve lever
2. Set the valve lever to the "RÜCKSPÜLEN" (BACKFLUSH) position and release it.
3. Allow the filter vessel
4. Check the filter system and the connections for leaks.
5. Backflush the system (see section "Backflushing").
Operation
A damaged device or damaged accessories may cause injuries.
- Check the device and the accessories (see section "Testing").
Selecting the mode
Switch the pump
off by pulling the power plug.
3
Press and hold down the valve lever
position and let go.
Starting the pump
Check the valve setting of your filter system before you activate the pump.
Connect the pump's power plug to the power supply.
The pump is running. Listen to the pump to check for any unusual noises. If there is air in the system,
bleed it again.
To stop pump operation, pull the power plug.
Care instructions
The filter system cannot filter out algae, bacteria and other microorganisms.
- Use special water care substances to prevent and remove these to ensure hygienically clean
water.
- Consult an expert and observe the dosage.
32
on the valve head
22
to fill with water until the water runs out of the "WASTE"
2
CAUTION!
Risk of injury!
on the valve head
22
12
.
1
. Turn the valve lever to the desired
1
PUMP
RETURN
backflush line.
21