8 Detecting and removing malfunctions
Malfunction
Motor does not rotate
Motor rotates, but does
not convey or too little
Flow rate too low
Thermal switch shuts off
the pump
Flat suction pump FSP 330
Cause
• Supply voltage missing
• defective power cable
• Impeller blocked
• Activated motor protection
(overheating, blockage, volt-
age error or other defect)
• Motor defective
• Impeller clogged or worn
• Pressure line clogged or hose
kinked
• Pump not properly ventilated
(air bubble in the housing)
• Pressure line dimensioned
too small
• Motor overloaded, because
friction too high through con-
tamination in pump housing
Troubleshooting
• Check if the plug is in the outlet
• Replacement (customer service)
• Clean impeller
• Check and inform customer service
• Replacement, (Customer service)
• Clean or replace, inform customer
service, if necessary
• Clean the pressure line, remove kink
• When commissioning the pump, bleed
the pressure line so that water gets
into the pump housing
• minimum diameter 25 mm (1")
• Dismantle and clean pump,
Reduce suction of foreign objects