Starting Operation

Please observe all regulations
and guidelines governing the
safe use of liquid gas in your
area (in Germany, the technical
rules for liquid gas TRF 1988 as
well as the professional
association guidelines for the
use of liquid gas ZH 1/455)
when using the heater.
Follow the instructions listed
below in the order they are
presented.
1. Plug in the mains cable
(230 V ~ 50 Hz)
2. Screw-fasten flexible gas tube
with pressure reducer and
integrated tube rupture
protective device to the gas
valve (the tightness of the
screw couplings must be
ensured). Open the gas
cylinder valve. * Actuate the
push button of tube rupture
protective device. *
3. Press the ON-OFF switch.
Check by eye (from the air
inflow side) if the ventilator
motor is rotating.
4. Press the gas valve button and
simultaneously press the
ignition button repeatedly until
the burner ignites (only if the
ventilator is rotating).
5. To switch off the heater,
always first close the gas
cylinder valve and only then
turn off the ventilator motor.
06.11.2001 13:53 Uhr
Seite 7
Fuel
Make sure that only propane /
butane are used. The appliance
can be operated in conjunction
with any 5 kg or 11 kg gas
cylinder or an even bigger
container. To connect the
appliance to the gas cylinder,
make sure that only a pressure
reducer with an output pressure
of 1,5 bar as per DIN 4811, part
1, and a liquid-gas flexible pipe to
DK 6 as per DIN 4815, part 2, is
used.
pressure
reducer
Hose rupture
safety device

Heating capacity

The heating capacity can be
adjusted between 19 and 30 kW
with the regulator valve.
Ventilation
Caution:
The heater must only be used in
well ventilated areas (heater is
not intended for use in enclosed
spaces). The continuous
presence of persons in these
rooms is forbidden. If more than
one heater is used in one room,
be sure to provide for
correspondingly more fresh air
circulation.