5. Before starting the equipment

5.1 Assembly
Assemble the foot, wheels and push bar as
shown in Figures 6-9.
Assemble all parts before filling in fuel and oil
in order to prevent the fluids from leaking out.
To mount the wheels, first slide the axle
through the mountings on the bottom of the
generator and fit the wheels as shown on
Figure 7.
5.2 Electrical safety:
Electric supply cables and connected equip-
ment must be in perfect condition.
The generator is to be operated only with
equipment whose voltage specifications con-
form with the generator's output voltage.
Never connect the generator to the power
supply (socket-outlet).
Keep the cable length to the consumer as
short as possible.
5.3 Environmental protection
Dispose of soiled maintenance material and
operating materials at the appropriate collec-
tion point.
Recycle packaging material, metal and plas-
tics.
5.4 Connecting to earth
The housing is allowed to be connected to earth
in order to discharge static electricity. To do this,
connect one end of a cable to the earth connec-
tion on the generator (Fig. 4) and the other end to
an external earth (for example an earthing rod).

6. Operation

Important! You must fi ll up with engine oil and
fuel before you can start the engine.
Check the fuel level and top it up if necessary
Make sure that the generator has sufficient
ventilation
Make sure that the ignition cable is secured to
the spark plug
Inspect the immediate vicinity of the gene-
rator
Disconnect any electrical equipment which
may already be connected to the generator
Anl_TC_PG_3500_W_SPK9.indb 19
Anl_TC_PG_3500_W_SPK9.indb 19
GB
6.1 Starting the engine
Open the petrol cock (13) by turning it down
Move the ON/OFF switch (10) to position
„ON" with the key.
Move the choke lever (11) to position IØI.
Start the engine with the reversing starter (12)
by pulling the handle forcefully. If the engine
does not start, pull the handle again.
Push the choke lever (11) back again after
the engine has started.
Important!
When starting with the reserve starter, the motor
may recoil suddenly as it starts up, resulting in
hand injuries. Wear protective gloves when star-
ting the equipment.
6.2 Connecting consumers to the generator
Connect the equipment you want to use to
the 230 V~sockets (3).
Important: These sockets may be loaded con-
tinuously (S1) with 2600W and temporarily (S2)
for a maximum of 5 minutes with 2800 W or for a
maximum of 2 minutes (with a cold motor) with
3100W.
The generator is suitable for 230 V~ AC appli-
ances only.
Do not connect the generator to the
household mains system as this may result
in damage to the generator itself or to other
electrical appliances in your home.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power con-
sumption when used in diffi cult conditions.
Some electrical appliances (for example televisi-
ons, computers, etc.) must not be powered by a
generator.
If in doubt, consult the manufacturer of your ap-
pliance.
6.3 Overload cut-out 2 x 230 V socket-outlets
Important! The generator is fi tted with an
overload cut-out.
This shuts down the sockets (3). You can restart
the sockets (3) by pressing the overload cut-out
(5).
Important! If this happens, reduce the electric
power you are taking from the generator or remo-
ve any defective connected appliances.
Important! Defective overload cut-outs must be
replaced only by overload cut-outs of identical