Herunterladen Diese Seite drucken

Delabie NT 778KIT Montageanleitung Seite 15

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
OPERATION
• Press the push-button control to open the valve.
• Automatic timed shut-off after ~ 3 or 7 seconds.
CHARACTERISTICS
• Pressure: 1 - 5 bar (100 - 500kPa), we recommend 3 bar (300kPa).
• Base flow rate for conventional urinals: 0.15 L/sec. at 3 bar.
• Max. flow rate for TEMPOFLUX, at 1 bar: 0.15 L/sec. - at 2 bar: 0.28 L/sec - at 3 bar: 0.40 L/sec.
• Calculate the pipe work according to the probable flow rate and the dynamic pressure.
• Connect the TEMPOMATIC 4 to the pipe work using a pipe with a minimum internal diameter of 12mm.
INSTALLATION
THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL OR THE WALL
PLATE AND THE MIXER AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall. DELABIE cannot be held responsible
for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821.
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
REMEMBER
• Our valves must be installed by professional installers in accordance with current regulations and
recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency
of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer/tap/valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
EN
EN

Werbung

loading

Diese Anleitung auch für:

Tempoflux778700778707778box778mbox