6. Maintenance
Although the poker vibrator has a few moving parts, regular maintenance promotes a long and trouble-
free life.
Warning: Disconnect the electrical supply to the poker vibrator, before you can carry out any
maintenance activities to the poker vibrator.
6.1 Cleaning the ventilation caps
The ventilation slots on both sides of the motor housing should be kept open at all times, in order to
achieve a maximum cooling effect. Check them at the end of each working day. If the ventilation caps
are not open, then clean the ventilation caps as follows:
Figure 8: Cleaning the ventilation caps
1. Remove the three screws from one of the ventilation caps.
2. Remove the ventilation cap from the motor housing.
3. Clean the inside and outside of the ventilation cap with a brush and water.
4. Under the left side ventilation cap (air-intake side), an air filter is mounted. If the ventilation caps
must be cleaned, also the air filter must be renewed.
5. Careful: Ensure that no water gets into the motor housing.
6. Clean the direct area of the ventilation opening in the motor housing, with a damp cloth.
7. Renew the air filter.
8. Place the ventilation cap over the ventilation opening in the motor housing. Ensure that the holes
in the ventilation cap are in a direct line with the holes in the motor housing.
9. Attach the ventilation cap to the motor housing with three screws.
10. Carry out the same operation in this section for the other ventilation cap.