4. Battery and Charger
4.1 Charger Requirements
The charger should only be used for charging the batteries. Do not
use your scooter while it is charging.
Charger Technical Data
Input voltage:
AC220V (110V) ±10%
Output voltage:
36V/DC Output current: 1.5~5A
Ingress protection level: IPX1
Meets requirement:
GB 4706.1-2005 and GB 4706.18-2005
4.2 Charger Use and Care
IMPORTANT:
- A full charge requires between 5 to 8 hours, do not overcharge more
than 10 hours.
- To prevent shortening your battery's life, charge the battery at least
once per month when the wheelchair is not being used.
- Do not stop charging until the charging process is finished.
- Repeat use of less than fully charged batteries will shorten the life
cycle of your battery.
- When battery is fully charged, the power indicator will turn green. Do
not stop charging before fully charged this indicator is lit.
- After charging is complete, ensure to turn off the power supply other-
wise the battery will discharge slowly.
- Do not charge more than 10 hours. Over-charging is dangerous.
Follow These Rules to Avoid Issues with Chargers
- The charger should be well ventilated at all times during charging.
- Do not expose the wheelchair to sunlight and humid environment.
- While charging, the temperature range should be between 50°F to
104°F (10°C to 40°C)
- If charged at temperatures outside of this range, the battery can be
damaged.
- Never use or sit on the electric scooter when charging.
14