The scope of delivery of the 800-CON transfer
5. Check the fit of your measurement-device and
5. Check the fit of your measurement-device and
modules (set of 2) includes an input and an
module series and mount end brackets.
module series and mount end brackets.
output bus connector, so that each transfer
o
800-CT8-A module
module can be used with the corresponding bus
800-CON module
800-CT8-A module
connector at the output or input of a series of
measurement devices and modules.
at
your
ng
Fig.: Output bus con-
nector for the 800-CON
t
transfer module (1 HP,
ted
see Technical data) at
ec-
the output of a series of
measurement devices
ule
and modules.
coupled bus connectors
coupled bus connectors
Fig.: Input bus con-
(internal)
(internal)
nector for the 800-CON
transfer module (1 HP)
at the input of a series
of measurement devices
and modules.
ut
r
8
Example of a measuring device and module topology with the
Example of a measuring device and module topology with the
8
3. Press the 2nd transfer module with input bus
800-CON transfer modules (set of 2)
800-CON transfer modules (set of 2)
connector onto the DIN rail until the bottom bolts
audibly engage.
ce
4. Mount further modules (e.g. current measu-
ring modules, digital input modules) and push
their contacts into the sockets of the input bus
connector so that the devices are coupled to the
transfer module 800-CON.
ply
or
800-CON module with
,
input bus connector
tor
s
Sockets of
the input bus
connector
Bottom bolt
click!
Example: Mounting of the 800-CON transfer module with input bus connector of the remote measuring
point
Example of a measuring device and module topology.
Example of a measuring device and module topology.
ATTENTION
Improper handling may cause damage to the
module and result in material damage!
The contacts of the bus connectors (JanBus
800-CON module
interface) can bend or break off and destroy the bus
connector.
· Never touch or manipulate the contacts of the
bus connector!
· Never force the bus connector into the module!
· When handling, transporting and storing
the module, protect the contacts of the bus
connector!
End bracket
End bracket
INFORMATION
· Always install the 800-CON transfer module with
output bus connector at the end of your measuring
DIN rail
DIN rail
device and module topology and the 800-CON
transfer module with input bus connector at the
beginning of your remote measuring point!
· In addition to the usage information for the basic
device and the 800-CON transfer module (set of 2),
please also note any other usage information for
the modules and components integrated in your
JanBus topology.
5. Check the fit of your device and module series
and mount end brackets.
6. Finally, wire your series of measurement devices
and modules, observing the usage information
for all integrated devices and modules.
7. Apply voltage to the basic device (system). The
basic device detects the modules automatically.
2. transfer module 800-CON (with
input bus connector) in the remote
measuring point with further modules
End bracket
DIN rail
DIN rail
Mounting the module with output bus connector
5
6
Mounting the module with input bus connector
6
Mounting the module with input bus connector
While observing the mounting instructions for your
For remote rows of modules, install the 2nd 800-
For remote rows of modules, install the 2nd 800-
basic device or the connected module (e.g. check
CON transfer module from the set with input bus
CON transfer module from the set with input bus
the bus connector mounting!), mount the 1st 800-
connector when the system is de-energized:
connector when the system is de-energized:
CON transfer module with output bus connector
when the system is disconnected from the power
supply as follows:
Bottom
bolts
Bottom
Bottom
bolts
bolts
Fig.: Module 800-CON - rear view (with output bus connector)
Fig.: Module 800-CON - rear view (with input bus connector)
Fig.: Module 800-CON - rear view (with input bus connector)
Connection of a series of devices and modules with transfer modules (set of 2)
7
9
Dismounting
9
Dismounting
For fault-free operation of your devices and
Dismounting the transfer module 800-CON:
Dismounting the transfer module 800-CON:
therefore your system, connect your transfer
1. Disconnect the system from the power supply! Secure
modules via shield terminals. The shield
1. Disconnect the system from the power supply! Secure
it against being switched back on! Verify disconnection
connection serves as protection against
it against being switched back on! Verify disconnection
from power! Ground and short circuit! Cover or block off
overvoltages and electromagnetic disturbances.
from power! Ground and short circuit! Cover or block off
neighboring parts that are under voltage!
neighboring parts that are under voltage!
2. Disconnect the wiring and the terminal.
Module
2. Disconnect the wiring and the terminal.
800-CT8-A
3. Remove or shift the shield terminal and end brackets of
3. Remove or shift the shield terminal and end brackets of
your series of devices and modules.
your series of devices and modules.
4. Decouple the bus connector (JanBus interface) of
4. Decouple the bus connector (JanBus interface) of
the transfer module from the basic device and/or the
the transfer module from the basic device and/or the
connected module by pulling it out.
connected module by pulling it out.
5. Unlatch the bottom latches of the transfer module.
5. Unlatch the bottom latches of the transfer module.
Recommendation: Use a screwdriver for this
Recommendation: Use a screwdriver for this
(carefully!).
(carefully!).
6. Remove the DIN rail from the transfer module without
6. Remove the DIN rail from the transfer module without
touching or damaging the bus connector contacts.
touching or damaging the bus connector contacts.
End bracket
ATTENTION
Handling your module too roughly may cause
Handling your module too roughly may cause
damage to the module and result in property
damage to the module and result in property
damage!
damage!
The bus connector contacts and the bottom latches
The bus connector contacts and the bottom latches
can be damaged or broken off during dismantling of
can be damaged or broken off during dismantling of
your module.
your module.
· Never wrench the module from the DIN rail
· Never wrench the module from the DIN rail
Fig. Example of "Device and module series":
using force.
using force.
· Decouple the bus connector (JanBus interface)
· Decouple the bus connector (JanBus interface)
Wiring of the transfer module (output)
beforehand and carefully unlatch the bottom
beforehand and carefully unlatch the bottom
latch of the module using a screwdriver!
latch of the module using a screwdriver!
9 / 10
1. Press in the open bottom bolts on the rear of
1. Press in the open bottom bolts on the rear of
1. Press in the open bottom bolts on the rear of
the module.
the module.
2. If not already done, plug the output bus
the module.
2. If not already done, plug the input bus
2. If not already done, plug the input bus
connector (JanBus interface) included in the
connector (JanBus interface) included in the
connector (JanBus interface) included in the
scope of delivery into the sockets on the back
scope of delivery into the sockets on the back
scope of delivery into the sockets on the back
of the module.
of the module.
of the module.
Output bus
Output bus
connector
Input bus
Input bus
Input bus
Input bus
connector,
connector
connector
connector,
connector,
rotated
rotated
rotated
Screwdriver for
Screwdriver for
unlatching
unlatching
Also provide a tension relief during the assembly,
which protects against unintentional tearing out
of the data cable. Use a 1:1 line connection for
Bus connector
the data cable and observe the following warning
notices!
Transfer module
JanBus
800-CON
interface
Shielded
data cable
Bus connector
Tension relief
Bottom latch
Fig.
Fig.
Dismounting the
Dismounting the
DIN rail
transfer module
transfer module
Shield terminal
ATTENTION
Property damage due to dismantling or
Property damage due to dismantling or
End bracket
decoupling the module during operation!
decoupling the module during operation!
Heat shrink tubing
Dismantling or decoupling the module while it is
Dismantling or decoupling the module while it is
communicating with the basic device can lead to
communicating with the basic device can lead to
damage to your devices!
damage to your devices!
· Disconnect your system from the power supply
· Disconnect your system from the power supply
before dismantling or decoupling the module!
before dismantling or decoupling the module!
Secure it against being turned back on! Verify
Secure it against being turned back on! Verify
disconnection from power! Ground and short
disconnection from power! Ground and short
circuit! Cover or block off neighboring parts that
circuit! Cover or block off neighboring parts that
are under voltage!
are under voltage!
Press the bus
Press the bus
Press the bus
connector
connector
connector
contacts of the
contacts of the
contacts of the
output bus
input bus
input bus
connector into
connector into
connector into
the module
the module
the module
sockets
sockets
sockets
10
Bottom latch
Bottom latch
Bus connector
contacts
contacts
DIN rail
DIN rail
Transfer module
Module
JanBus
800-CON
800-CT8-A
interface
Bus connector
sockets
sockets
Bottom latch
Terminal
Terminal
ATTENTION
ATTENTION
Fig. Example "Remote module series":
Wiring of the transfer module (input)