IMPORTANT: ONLY THERMO FIREPLACES WITH
COILS DRIVEN BY A THERMAL RELIEF VALVE
SHOULD BE INSTALLED ON CLOSED TANK SY-
STEMS (version marked with the abbreviation CS).
• The installer is responsible for the correct installation of the
system, which is to be compliant with UNI standards 10683 –
9615/90 – 10412:2
• All must be performed by quali ed personnel according to
Ministerial Decree 37 ex Law 46/90
The thermal relief valve (TRV - provided by Edilkamin) must
be connected to the cooling circuit (AL) with a minimum
pressure of 1.5 bar.
JA = automatic relief valve
S = drain
Litres ?
• The heating system must include an expansion tank dedicated
only to the thermo replace, evaluated based on the volume of
water present in the system itself (an expansion tank shared with
other generators is not allowed).
1 Year
• The safety and thermal relief valves must be checked at least
once a year by quali ed personnel according to Ministerial De-
cree 37 ex Law 46/90.

SAFETY INFORMATION

- 22
H
OCEANO MUST NEVER BE MADE TO OPERATE WI-
2
THOUT WATER IN THE SYSTEM.
MUST BE MADE WITH A PRESSURE OF ABOUT 1.5 BAR.
IT CAN BE DAMAGED IF IT IS IGNITED WITH NO WA-
TER IN THE SYSTEM.
• The thermo replace is designed to heat water by means of
wood combustion in the hearth.
• The only hazards that can derive from using the thermo re-
place pertain to non-compliance with the installation instruc-
tions, direct contact with live electrical parts (inside), contact
made with the re and hot parts or foreign substances being put
in the replace.
• For the thermo replace to function properly installation
must be carried out according to the instructions given in this
booklet and the door must only be opened to re ll the hearth
with wood.
• Never put foreign substances in the hearth.
• Whilst functioning, the door must never be opened. In fact,
combustion is fully automatic and requires no manual interven-
tion.
• Do not use ammable products to clean the smoke channel
(the ue section connecting the boiler- replace smoke outlet to
the chimney ue).
• The glass can be cleaned when COLD with a suitable product
(e.g. GlassKamin) and a cloth. Do not clean when hot.
• The exhaust pipes and the door become very hot when the
thermo replace is used.
• Do not place anything that is not heat resistant close to the
thermo replace.
• NEVER use liquid fuel to ignite the thermo replace or to
rekindle the embers.
• Do not obstruct the external air inlets in the room where the
replace is installed or the air inlets of the thermo replace
itself.
• Do not wet the thermo replace and do not go near the elec-
trical parts of the system with wet hands.
• Do not use reducers on the smoke exhaust pipes.
• The thermo replace must be installed in a place that is sui-
table against re hazards and equipped with all that is required
(power and air inlets/outlets) for it to function properly and
safely.
-