Changing the parameter setting on the tool (Field Setting mode)
NOTICE:
This function is available by default. If you have disabled the Field Setting mode on the computer,
enable the Field Setting mode beforehand. Refer to the instruction manual of "Makita Industry Tool Settings" for
how to configure.
NOTICE:
If the Field Setting mode is disabled, making settings on the tool is not available. When you press the
setting button, the values set on the tool are displayed in order.
NOTE: When the reversing switch lever is depressed in the clockwise rotation, the indicator shows the setting of
clockwise rotation.
When the reversing switch lever is depressed in the counterclockwise rotation, the indicator shows the setting of
counterclockwise rotation.
The current setting number is displayed on the indicator.
Every time you press the setting button, the indicator shows torque level, rundown level, shortest workable time
range, longest workable time range, and "Ad."
► Fig.7: 1. Setting button 2. Indicator
You can change the parameters of the following setting items.
Setting item
Torque level
Rundown level
Shortest workable time range
Longest workable time range
NOTICE:
If "OP" (Loosening Auto Stop mode) is displayed on the indicator, torque level setting and rundown
level setting is not available. To set the torque level and rundown level, change the mode to Tightening Auto Stop
mode on the computer using "Makita Industry Tool Settings".
Changing the torque level
Example: When changing the torque level from 23
to 34
► Fig.8
1.
Press the setting button several times until the
indicator shows 2-digit number which stands for
the current setting of the torque level.
2.
Press and hold the setting button until the number
in the tens place starts blinking.
3.
Set the number in the tens place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "4" in a cycle.
4.
Press and hold the setting button until the number
in the ones place starts blinking.
5.
Set the number in the ones place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" in a cycle.
6.
Press and hold the setting button for a few
seconds.
NOTE: If you are not sure which torque level is suit-
able for your work, set "FF" so that the tool operates
in the Free mode.
NOTE: If you input "00", "FF" is displayed instead of
"00".
Display on the indicator
01 - 40
FF
L1 - L7
Lo / 0.1 - 9.9
Lo / -.-
HI / 0.1 - 9.9
HI / -.-
Changing the rundown level
Example: When changing the rundown level from
L1 to L2
► Fig.9
1.
2.
3.
4.
Changing the shortest workable time
range
Example: When changing the shortest workable
time range from 2.5 to 3.6
► Fig.10
1.
2.
9 ENGLISH
The torque level at which the Tightening
Auto Stop mode works.
The sensitivity of the fastener seating.
The shortest duration of the rotation when
you continue to pull the switch trigger.
The longest duration of the rotation when
you continue to pull the switch trigger.
Press the setting button several times until the
indicator shows 2 characters beginning with "L"
followed by a number. This stands for the current
setting of the rundown level.
Press and hold the setting button until the indica-
tor starts blinking.
Set the rundown level. Every time you press the
setting button, the indicator shows from "L1"
to "L7" in a cycle. The highest sensitivity of the
fastener seating is "L1" and "L7" is the lowest
sensitivity.
Press and hold the setting button for a few
seconds.
Press the setting button several times until the
indicator shows "Lo" and number alternatively.
This stands for the current setting of the shortest
workable time range.
Press and hold the setting button until the number
in the ones place starts blinking.
Description