ATTENTION!
•
Risk of injury from environment!
There can be malfunctions on component due to condensation and/ or icing.
THEREFORE:
•
Observe suitable temperatures.
•
Protect component from liquids from outside
•
Protect component from dust from outside
•
Protect component from weather conditions
•
Grounding has to be mounted properly
WARNING!
•
Risk of injury from using oil and grease!
Oil and grease must never be used in gas regulating systems. Oil and grease are highly infl ammatory and
can react violently to certain pressurized gases.
THEREFORE:
•
Never use oil and grease
WARNING!
•
Risk of injury from residual energy stored in the system!
If handled incorrectly, pressurized components can move uncontrollably and cause severe injury. If handled
incorrectly or defective, pressurized components can leak gas under high pressure and cause severe or
even fatal injuries.
BEFORE STARTING WORK WITH THESE COMPONENTS:
•
Installation only through certifi ed company.
•
Always wear protective goggles when working.
•
Always wear ear protection.
•
Make sure the equipment is depressurized. Also make sure the residual energy is discharged.
•
Always ensure that gas cannot leak unintentionally.
•
Make sure that defective components that are pressurized during operation are immediately replaced by
trained sta .
WARNING!
•
Danger of accident!
Due to wrong installation there can be serious or even mortal injuries.
THEREFORE:
•
During installation the component should be kept safe
•
Never throw the component
Pressurised components are only for intended use.
If there are mechanical damages at tubing or components the whole system has to be put in a safe condi-
tion. A ected area has to be blocked. Troubles which could infl uence safety, have to be eliminated through
qualifi ed sta or supplier.
Especially with gases failure in pressure regulator could happen. Indications for defective regulator is no fl ow
or immediately rising outlet pressure. In this case system has to be shut-o and the relevant department for
maintenance has to be informed. Never close exhaust piping.
2.3. OPERATOR'S RESPONSIBILITY
OPERATOR
The operator is the person who operates the system for commercial or business purposes or who provides
the system for use/application by a third party, and who bears legal product responsibility for protecting the
user, sta or third parties during operation.
OPERATOR'S DUTIES
The system is used for commercial purposes. The operator of the system is therefore subject to legal work
safety obligations.
Compliance with the safety, accident prevention and environmental protection regulations that apply for the
use of the system is mandatory, in addition to the safety information in these instructions.
7/44