5 Troubleshooting
5 Troubleshooting
LED indicator
System
Not lit
Red
Port 1
Not lit
Orange
Port 2
Not lit
Orange
Port 3
Not lit
Orange
Note
"Unlit" port LEDs do not indicate a fault.
38
All manuals and user guides at all-guides.com
Possible causes
– Failure of supply voltage
– Internal device fault
– No data received at Port 2 and/or Port 3, e.g. cable breakage
– No data received at Port 1, e.g. no participant at Port 1
– No input signal received at any of the 3 ports for over 500 ms
– Short circuit at the electrical port
– Currently no input signal at this port
– No input signal received at any of the 3 ports for over 500 ms
– Short circuit at the electrical port
– Currently no input signal at this port
– No input signal received at any of the 3 ports for over 500 ms
– Currently no input signal at this port
– No input signal received at any of the 3 ports for over 500 ms
Signaling contact
Signal
Signal
Signal
Signal
Signal
OZD FIP G3 ...