Thank you for choosing this instrument from TFA.
1. Before you use this product
Please make sure you read the instruction manual carefully.
• Following and respecting the instructions in your manual
will prevent damage to your instrument and loss of your
statutory rights arising from defects due to incorrect use.
• We shall not be liable for any damage occurring as a result of
non-following of these instructions.
• Likewise, we take no responsibility for any incorrect read-
ings or for any consequences resulting from them.
• Please take particular note of the safety advice!
• Please keep this instruction manual safe for future reference.
2. For your safety
• This device is only to be used for measuring human body tem-
perature through oral, rectal or axillary measuring method.
Do not attempt to take temperatures at other sites, such as in
the ear, as it may result in false readings and may lead to
injury.
• Before each measurement check intactness of tip and display.
Use the device only when intact.
• Unauthorised repairs, modifications or changes to the pro-
duct are prohibited.
• Operation in strong electromagnetic fields, such as next to a
mobile phone, can lead to malfunction. Keep a minimum dis-
tance of 3.3 m from such devices when using this device.
• The minimum measurement time until the beep must be
maintained without exception.
• Consider that different measurement locations may require
continued measuring even after the beep, see section «Mea-
suring methods / Normal body temperature».
• Do not attempt rectal measurements on persons with rectal
disorders. Doing so may aggravate or worsen the disorder.
• WARNING: The measurement result given by this device is not
a diagnosis! Do not rely on the measurement result only. Dis-
cuss the measured values with your doctor.
• The manufacturer recommends to verify the accuracy by an
authorised laboratory every 2 years.
Caution!
Risk of injury:
• The instrument contains small parts that could be swallowed
by children. Keep this instrument and the battery out of
reach of children. Use under parental supervision.
• Batteries contain harmful acids and may be hazardous if
swallowed. If a battery is swallowed, this can lead to serious
internal burns and death within two hours. If you suspect a
battery could have been swallowed or otherwise caught in
the body, seek medical help immediately.
• Batteries must not be thrown into a fire, short-circuited,
taken apart or recharged. Risk of explosion!
• Low batteries should be changed as soon as possible to pre-
vent damage caused by leaking. Avoid contact with skin, eyes
and mucous membranes when handling leaking batteries. In
case of contact, immediately rinse the affected areas with
water and consult a doctor.
• Remove the battery if you do not use the product for a long
period of time.
Important information on product safety!
• Protect the device from impact and dropping!
• Do not bend the instrument.
• Avoid ambient temperatures above 40 °C. NEVER boil this
device!
• Use only the commercial disinfectants listed in the section
"Cleaning and Disinfecting" to clean the device to avoid
damage to the device.
3. Elements and buttons
A: Battery compartment
B: ON/OFF button
C: Low battery symbol
D: Display for the temperature
E: Measuring sensor / measuring tip
4. Use
• Disinfect the tip before each use!
• Press the ON/OFF button.
• When the device is switched on, a beep sounds and all seg-
ments are briefly displayed.
• The last measured temperature appears briefly on the dis-
play. The device performs a self-test and 37.0 °C is displayed.
Then °C flashes and Lo appears (if the room temperature is
below 32 °C). The device is now ready for use.
• The measured maximum temperature is permanently shown
during the measurement and °C flashes.
• If the maximum temperature remains stable (change < 0,1°C
in 16 seconds), °C stops flashing and an alarm will sound for
10 seconds:
a) Normal alarm (beep ... beep ... beep ...), body temperature
below 37.8 °C
b) Fever alarm (beep beep beep ...), body temperature 37.8
°C or above
• Hi °C will be displayed, when the measured temperature is
higher than 42.9 °C.
16:01 Uhr
Seite 2
D
C
B
A
• Remove the thermometer carefully. Press the ON/OFF button
to switch off the instrument. The instrument will turn off
automatically after approx. 9 minutes.
4.1 Measuring methods / Normal body temperature
In the mouth (oral) / 35.5 - 37.5 °C
• Do not eat or drink anything hot or cold 10 minutes before the
measurement. The mouth should remain closed for 2 minutes
before starting a reading.
Position the thermometer in one of the two pockets under the
tongue, to the left or right of the root of the tongue. The
measuring sensor must be in good contact with the tissue.
Close your mouth and breathe evenly through the nose to pre-
vent the measurement from being influenced by inhaled/
exhaled air.
Approx. measuring time: 1 minute
In the anus (rectal) / 36.6 - 38.0 °C
• Carefully insert the measuring sensor 2 to 3 cm into the anal
aperture.
You may consider using a lubricant. If you are unsure of this
measurement method, you should consult a professional for
guidance/training.
Approx. measuring time: 1 minute
In the armpit (axillary) / 34.7 - 37.3 °C
• To receive more reliable results, we recommend measuring
temperature orally or rectally. A minimum measurement time
of 5 minutes is recommended regardless of the beep sound for
axillary measurement.
5. Cleaning and disinfecting
• For disinfection in home use environment, use a 70% Iso-
propyl alcohol swab or a cotton tissue moistened with 70%
Isopropyl alcohol to wipe surface pollutants off the ther-
mometer probe. (Note: Observe the application and safety
instructions of the disinfectant manufacturer). Always start
wiping from the end of the thermometer probe (approx. at
the middle of the thermometer) towards the thermometer
tip.
• Contact your retailer for further details concerning suitable
disinfectants for your thermometer model.
5.1 Battery replacement
• Change the battery when the display starts to fade or the
battery symbol appears on the display.
• Remove the battery cover by pulling it backwards.
• Carefully remove the battery with a pointed object and insert
a new LR 41 battery. Make sure the polarity is correct (- pole
above).
• Do not pull out the battery holder. Otherwise, the device may
be damaged.
• Slide back the battery cover. Pay attention to the sealing ring.
6. Troubleshooting
Problem
Solution
No display
Switch on the instrument
Ensure battery polarity is correct (- pole above)
Change the battery
Incorrect display
Change the battery
Check the correct position of the thermometer
(see: Measurement methods)
Remove the battery.
Wait one minute and then reinsert the battery
If your device fails to work despite these measures, contact the
retailer where you purchased the product.
7. Legal basis for placing of the product in the EU market
• The Digital Thermometer TM01, Art.-No. 15.2008 is a medical
device class 2a according the EU Medical Device Directive
93/42/EWG.
• Standards: EN 12470-3 Medical Thermometer; IEC 60601-1,
IEC 60601-1-2 (EMC), IEC 60601-1-11
8. Waste disposal
This product and its packaging have been manufactured using
high-grade materials and components which can be recycled and
reused. This reduces waste and protects the environment.
Dispose of the packaging in an environmentally friendly manner
using the collection systems that have been set up.
Disposal of the electrical device
Remove non-permanently installed batteries and
rechargeable batteries from the device and dispose
of them separately.
This product is labelled in accordance with the EU
Waste Electrical and Electronic Equipment Directive
(WEEE).
This product must not be disposed of in ordinary
household waste.
Instruction manual
2460
Digital medical thermometer TM01
As a consumer, you are required to take end-of-life
devices to a designated collection point for the dis-
posal of electrical and electronic equipment, in
order to ensure environmentally-compatible dispos-
al. The return service is free of charge. Observe the
current regulations in place!
Disposal of the batteries
Batteries and rechargeable batteries must never be
disposed of with household waste. They contain
pollutants such as heavy metals, which can be
harmful to the environment and human health if
disposed of improperly, and valuable raw materials
such as iron, zinc, manganese or nickel that can be
recovered from waste. As a consumer, you are
legally obliged to hand in used batteries and
rechargeable batteries for environmentally friendly
disposal at retailers or appropriate collection points
in accordance with national or local regulations.
The return service is free of charge. You can obtain
addresses of suitable collection points from your
city council or local authority.
The names for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
Reduce the generation of waste from batteries by
using batteries with a longer lifespan or suitable
rechargeable batteries. Avoid littering the environ-
ment and do not leave batteries or battery-contain-
ing electrical and electronic devices lying around
carelessly. The separate collection and recycling of
batteries and rechargeable batteries make an
important contribution to relieving the impact on
the environment and avoiding health risks.
WARNING!
Damage to the environment and health
through incorrect disposal of the batteries!
9. Specifications
Type
Maximum thermometer
Measuring range
32 °C ... 42,9 °C
Display Lo °C
Surrounding temperature lower than 32 °C
Display Hi °C
Surrounding temperature higher than 42.9 °C
Accuracy:
±0.1 °C at 35 °C...42°C@22°C
±0.2 °C otherwise
Resolution:
0.1°C
10. Explanation of symbols
2460
Declaration of European conformity, number of the notified body DNV Product Assurance AS, Norway)
Device complies with protection class BF
Storage and transport conditions:
Temperature: -10 °C...+40 °C
Humidity: 30...90 % rH
Lot number
Manufacturer:
Cotronic Technology Ltd., Floor 4~6, Block 7, West of Zhoushi road, Xixiang street, Baoan zone, Shenzhen,
Guangdong, China.
EU Representative:
Wellkang Ltd, Enterprise Hub, NW Business Complex,1 Beraghmore Road, Derry, BT48 8SE, Northern Ireland, UK
Vertreiber:
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, 97877 Wertheim, Germany
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going
to print and may change without prior notice. The latest technical data and information about this product can be found in our homepa-
ge by simply entering the product number in the search box.
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
Made in P.R.C.
Art.-No.15.2008
Instruction manuals
www.tfa-dostmann.de/en/service/downloads/instruction-manuals
Storage and transport conditions
Temperature -10 °C...+40 °C /humidity: 30... 90 % rH
Ambient conditions by use
Temperature 10 °C...35 °C /humidity 40...80 % rH
IP protection class
IP22
Battery
LR 41 included
Average battery life
2 years
Housing dimension
19 x 10 x 128 mm
Weight
10 g (incl. battery)
Consult instructions for use
Ambient conditions by use:
Temperature: +10 °C...+35 °C
Humidity: 40...80 % rH
Revision Date: 2023-11-23 D/GB