OPERATION
• Hands must be placed at the 'U' shaped opening.
Hand dryer starts automatically after placing the
hands.
• Move hands in order to dry them completely.
• Green light (in standby state) led on top becomes
to yellow colour when dryer is in use.
• Maximum continuous operation time is T = 30 sec.
Drying time is less to it (Td ≈ 8 - 10 sec).
• After removing hands, dryer turns off
automatically.
FEATURES AND ADJUSTEMENTS
U-flow family of hand dryers offers the technical features as follows:
• Automatic operation. Drying cycle starts when placing the hands at the opening. A
couple of IR sensors detect the hands.
• Dryer is a class I (earthed) electrical insulation device.
• Drying process is based on powerful air curtains which remove water from hands.
• Speed of air can be adjusted in order to achieve an optimum balance between drying
power and noise level.
• Light led's at the side of the 'U' shaped opening supply some information referred to
the status of the hand dryer.
• Water from hands is collected in a double removable tank system which may be
emptied and cleaned.
• A filter is incorporated in the aspiration area whose state should be reviewed
periodically. The place of fitting the air inlet filter allows easy removal and replacement.
Optionally, in the aspiration area, an air-freshener can be incorporated.