Typical applications

Fig. 1-2.

Installation

Fig. 3 ÷ 17.

Wiring diagram

Fig. 18 ÷ 23.

Initial configuration

The installer must configure appliance operation by following the steps described later on.
Selecting the product model: see below. This step is carried out in the factory; the instructions provided in this
booklet may only be of use if it becomes necessary to reset the status following accidental tampering with the
dip-switch.
Selecting the operating mode: see below. There are two modes: with two speeds V1 and V2, which can be
selected via an external switch, or with speed that can be adjusted via an external potentiometer.
Setting the V1 and V2 values (for two-speed operating mode)
Selecting the product model
The model is selected by setting the dip-switch 1 indicated in the figure as described in the table below.
LINEO 100-160 ES
DIPSWITCH
ON
SW 1 : MODEL
OFF
SW 2 : SETUP
2
1
TRIMMER
1 2 3 4
Model
Int.1
LINEO 100 Q ES
OFF
LINEO 100 ES
OFF
LINEO 125 ES
OFF
LINEO 150 ES
OFF
LINEO 160 ES
OFF
SW1
Int.2
Int.3
Int.4
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF