Mounting
Mounting takes place using the supplied retaining unit on the wall or on a support rail
according to DIN EN 60715. The server is snapped onto the retaining unit.
Start-up
A current HTML5-compatible browser (input device) is required for access to SV-Home
and SV-Control.
Smart Visu Server, interface, network router (DHCP active) and input device
must all be part of the same network. During start-up, the Smart Visu Server expects the
assignment of an IP address via DHCP.
Remove the discharge protection (6) from the server. Connect the server to the network
(2) and the power supply unit to the server (3).
After the mains plug has been connected, the server will boot.
As soon as the Status LED (4) turns blue, the server is ready for operation.
In the address line of the Internet browser, enter:
http://sv-server.local
This opens the homepage of the server.
If the homepage is not opened, then determine the IP address of the server in the router
manually. Enter the determined address, e.g. 192.168.178.26, in the address line of your
Internet browser, e.g.:
This opens the homepage of the server.