The pump is equipped with an integrated check valve (non-return valve). It will prevent liquid from flowing back
from the pressure line into the pump after the pump is shut down and protect the unit from being damaged by
pressure peaks.
The pressure line is to be installed to the pressure port (5) of the pump.
5.3.
Installation of lowering rope
Fig.1
Thread the lowering cord supplied as shown in fig. 1, through the three eyes in the upper end of the pump. Then
fasten the cord with a double knot (fig. 2). Ensure that the lowering cord is fastened firmly to the pump.
5.4.
How to position the pump
To lower or raise the pump, please use a suitable lowering rope, but never the pressure hose
or the connection cable.
To lower the pump down into or lift it out of the liquid, one has to use a lowering rope suitable for this purpose.
Please use a rope made of stainless steel or synthetic materials such as nylon. Considering the risk of breaking
involved, ropes which tend to the formation of rust, weathering, mouldering etc must not be used. The rope does
not only have to bear the weight of the pump plus that of the water-filled pressure line and the connection cable, it
also has to resist to the strain occurring in operation.
The standard equipment of this model includes a high-grade lowering rope (1).
To fasten the rope to the pump, please use the two eyelets (2) located at the upper part of the unit. Make sure
that the pump will move into a vertical position when lifted up with the rope.
The lowering rope, the connection cable (3) and the pressure line have to be tied together at distance intervals of
about 2 m using a suitable adhesive tape or cable ties to keep them from getting entangled while the pump is
raised or lowered.
Carefully lower the pump with the lowering rope down into liquid to be discharged. Make sure that the unit will not
bump or rub against the circumference of the cavity. The unit must be fully immersed in the liquid.
The minimum distance from the ground should be 0.5 m to prevent sludge, sand, stones etc from being sucked in.
In order to be sure of this positioning it is advisable to set the pump down on the bottom of the well shaft and to
mark this submersion depth on the tensioned cord. Make a second marking 0.5 m below this (i.e. towards the
pump). Now draw the pump upwards 50 cm and fasten the device in place at this position whilst observing the
second marking. Please note that the maximum submersion depth of the pump in liquid is theoretical 150 m.
Without extension of the provided pump cable the maximum submersion depth represents 27 m. To avoid any
hazard, the potential extension of the cable should be done by the manufacturer or a by an authorised service
provider.
5.5.
Horizontal installation
Please call your attention to install position shown in Fig 3. To avoid any damage of the pump, the pressure port
should never be positioned moreover a horizontal installation.
For the horizontal installation a guarding cover shown in Fig.4 should be used. Make sure that the motor will be
protected from sloughing and sanding-up.
Fig. 3
12
Fig.2
Fig. 4
Underwater cable
Cable connector
SP Pump
Suction cover with
accessory parts