5. Technical Data
Type
Total output
Heat output (level 1 / level 2)
Motor output
Control possibility
Voltage
Electricity (ventilate / level 1 / level 2)
Air volume
IP class
Length x width x height
Weight
6. Troubleshooting
ERROR
Appliance does not start
up
Appliance heats up, fan
does not run
If the appliance is supplied with electricity by the mains cable, work to the electrical
system can only be carried out by specialist electrical staff or a person trained in
electrical appliances in accordance with DGUV V3.
Please only get repair work to the electrical appliance done by Dantherm service partners.
Discontinuing use and disposal of the appliance
The appliance has been designed for long term use.
If it has to be disposed of, please do so in accordance with the current relevant laws in an environment
friendly manner.
W
W
W
°C
V
A
m³ / h
mm
kg
CAUSE
1.
Main switch off
2.
Indoor fuses tripped.
3.
Internal fuse (13A) has been
activated.
4.
Plug has been pulled out of the
main switch panel or extension
cable.
5.
Supply line defective.
6.
Mains switched off
7.
Indoor residual-current-circuit
breaker has tripped
8.
Heating coil defective.
9.
Safety temperature limiter tripped
10. Fan defective
11
DE 9 XL
9000
4500 / 9000
52
0° - 40°
400
6,5 / 13
550
21
466 / 322 / 420
14,5
SOLUTION
Check up to what point
electricity is available.
Repair defect.
Wait until electricity returns.
Check safeguards.
Clean the heating coil
(possibly with compressed
air), otherwise send it for
repair. The unit may have
come into contact with
moisture. If so, allow to dry
thoroughly before operating.
Send appliance to be
repaired.
Reset STB
Send appliance to be
repaired
EN