sensor simultaneously, the components of the loading when added together must not
exceed 100 %
Example 1
You are using 50 % of the allowed lateral force, 25 % of the bending moment and 25 % of
the torque.
50 % + 25 % + 25 % = 100 %
u
The sensor is not overloaded and can be operated.
Example 2
You are using 70 % of the allowed lateral force, 25 % of the bending moment and 25 % of
the torque.
70 % + 25 % + 25 % = 120 %
u
The sensor is overloaded and must not be operated.
Lateral force
Fig. 7.1
Parasitic loads: Bending moments, lateral forces, torque and eccentric force
application
CFT+
MECHANICAL INSTALLATION
Eccentric force application
Bending moment
Torque
13