Herunterladen Diese Seite drucken

VOSS.farming Sunny 800 Bedienungsanleitung Seite 35

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
INSTRUCTION MANUAL VOSS.FARMING SUNNY 800
13
FENCE POWER SUPPLY CABLE AND GROUNDING CHECK
Check the fence voltage at the end of
Tip 2
Switch off device, connect
it to the fence and switch on
Check grounding > measure
voltage at grounding post!
Tip 6
42088 - 11.2022 - V5
1
the fence power supply cable!
Voltage over 6000 V?
YES
again
Check the voltage on the
fence with a fence tester.
Over 2.5/4 kV?
NO
2
Voltage at grounding post
over 1000 V?
YES
Improving the grounding
Checking the fence power supply cable
Tip 5
NO
Supply cable from device to
fence defective
YES
Problem solved
Checking the grounding
Tip 3
The fault is with the fence.
NO
Voltage loss because of poor
connections (knots, corroded
connectors/conductor
materials)
Check the voltage on the
fence with a fence tester.
Over 2.5/4 kV?
YES
Everything is fine
Tip 7
NO
35
DE
EN
FR
IT
NL
SV
ES
PL

Werbung

loading

Diese Anleitung auch für:

42088