Herunterladen Diese Seite drucken

VOSS.farming Sunny 800 Bedienungsanleitung Seite 33

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
INSTRUCTION MANUAL VOSS.FARMING SUNNY 800
Fault/Problem
Voltage loss/leakage on the
fence
Poor grounding
42088 - 11.2022 - V5
Solution
Remove vegetation from the fence (mowing, cutting back).
Check whether the insulators are defective (recognisable by
"cracking" and possibly sparking in the insulator). Replace
defective and weathered insulators.
Check whether the conductor material touches the ground (e.g.
due to breaks, insufficient tension). Repair the fencing, use
only special connectors and tension the conductor material.
Check whether the conductor material has unfavourable
properties (thin conductor, high resistance). Use high-
quality thicker conductor material with low resistance.
Ensure high quality wiring of the conductor material.
Make sure that the conductor material is not connected by
knots and that there is an adequate connection. Use suitable
special conductor connectors for the conductor material.
Follow the tips in section 7.4.
Check whether the earth rod is corroded. Replace corroded
earth rods.
Check that the cables/connections are intact. Replace
defective parts.
DE
EN
FR
IT
NL
SV
ES
PL
33

Werbung

loading

Diese Anleitung auch für:

42088