SYSTEM SETTINGS (Settings)
Press MODE until the top line of the display shows "Menu". Now select the "Settings" option (bottom line) using UP and DOWN and press
ENTER. You can now select the desired submenu item using UP and DOWN and confirm with ENTER (see table, status / change value with UP
and DOWN, confirm with ENTER):
Settings (bold = factory setting)
Display Rev
=
Display rotates by 180°
Display
=
Automatic display deactivation
DMX Fail
=
Operating status if DMX signal
is lost
Dim.Curve
=
Dimmer curve
Dimmer
=
Dimmer response
Resp.
Autolock
=
Automatically locks the control
elements
White
=
White balance
Balance
IR Remote
=
Activate or deactivate control via
the IR remote
Factory
=
Reset to factory settings
Reset
8
Display Rev On
Rotate display by 180°
(e.g. for overhead installation)
Display Rev Off
Normal display rotation
Display On
Permanently on
Display Off
Automatic deactivation of the display after approx. 1
minute of inactivity
Hold
Last command is kept
Blackout
Activates blackout
Linear
Light intensity increases linearly with DMX value
Exp
Light intensity can be finely adjusted at lower DMX
values and broadly adjusted at higher DMX values
Log
Light intensity can be broadly adjusted at lower DMX
values and finely adjusted at higher DMX values
S-curve
Light intensity can be finely adjusted at lower and
higher DMX values and broadly adjusted at medium
DMX values
LED
The spotlight responds abruptly to changes in the
DMX value
Halogen
The spotlight behaves like
a halogen spotlight with soft brightness changes
On
Automatically locks the control elements after approx.
1 minute of inactivity Display shows: "Locked!"
Unlock: Press UP and DOWN at the same time for
approx. 5 seconds
Off
Deactivates automatic locking of the control elements
Red, green, blue,
Individual white balance. Cross-mode configuration of
amber
the 4 colors RGBA (value 000–255)
On
Activate control via the IR remote
Off
Deactivate control via the IR remote
Reset Now?
ENTER = reset to factory settings
MODE = do not reset to factory settings