Herunterladen Diese Seite drucken

EINHELL TE-AC 270/50 Silent Plus Originalbetriebsanleitung Seite 18

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
10. Possible causes of failure
Problem
The compressor
does not start
The compressor
starts but there is no
pressure
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
For EU countries only
Never place any electric power tools in your household refuse.
To comply with European Directive 2012/19/EC concerning old electric and electronic equipment and
its implementation in national laws, old electric power tools have to be separated from other waste and
disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request:
As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment
must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment.
The old equipment can be returned to a suitable collection point that will dispose of the equipment in
accordance with the national recycling and waste disposal regulations. This does not apply to any ac-
cessories or aids without electrical components supplied with the old equipment.
Please note that batteries and lamps (e.g. light bulbs) must be removed from the tool before it is dispo-
sed of.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers ac-
companying products is permitted only with the express consent of the Einhell Germany AG.
Subject to technical changes
Anl_TE-AC_270-50_Sil_Pl_SPK13.indb 18
Anl_TE-AC_270-50_Sil_Pl_SPK13.indb 18
GB
Cause
1. No supply voltage.
2. Insuffi cient supply voltage.
3. Outside temperature is too low
4. Motor is overheated
1. Leak in the non-return valve
(14)
2. The seals are damaged.
3. The drainage cock for conden-
sation water has a leak.
1. Loose hose connections.
2. Leak in a quick-lock coupling.
3. Insuffi cient pressure set on the
pressure regulator.
- 18 -
Solution
1. Check the cable, power plug, fuse and
socket-outlet.
2. Make sure that the extension cable is
not too long. Use an extension cable
with large enough wires cross-sections.
3. Do not use at an outside temperature
below +5° C.
4. Allow the motor to cool down. If neces-
sary, remedy the cause of the overhe-
ating.
1. Replace non-return valve (14)
2. Check the seals and have any dama-
ged seals replaced by a service center.
3. Check the drainage cock and replace if
necessary.
1. Check the compressed air hose and
tools and replace if necessary.
2. Check the quick-lock coupling and re-
place if necessary.
3. Increase the set pressure with the pres-
sure regulator (3).
12.06.2023 11:02:27
12.06.2023 11:02:27

Werbung

loading

Diese Anleitung auch für:

40.206.20