Connection of power supply (green terminal pin 9- / 7+):
Type of power supply
Direct supply of the transmitter
supply unit
Power supply via pac-Bus
Input connections (blue terminals PIN 10,11,12):
Two-wire-
Three-wire-
transmitter
transmitter
12 +
10
Note: A working HART communication requires a minimum load resistance (e.g. input
resistance of input card) of 250 Ω in the output circuit. If this is not available an external
resistance can be used. The maximum output load is reduced accordingly.
7.2 Setting of line fault detection (only 9162/13-11-12)
Line Fault detection LF
Deactivated *
OFF
ON
LF
*) Default factory setting
The DIP switch settings may be changed during operation in Zone 2 as well and in the
case of connected, intrinsically safe input signals.
The line fault detection is always activated with the version 9162/13-11-14.
How to connect
Green terminal PIN 9- and 7+
See chapter 6.3 c)
mA-source
12 +
11 -
10
Activated
OFF
ON
LF
Transmitter supply unit with limit values type 9162
Operating instructions
11 -
10