5 INSTALLATION

5.1 Rack installation

Install the unit on a plane surface or in your rack. For 19" (483 mm) rack installation, 3 units are required.
When mounting the unit into the rack, please make sure that there is enough space around the device so
that the heated air can be passed on. Steady overheating will damage your device. You can fix the unit with
four screws M6 in the rack.

5.2 Connecting audio devices

Switch off the MZD-860 prior to connecting any units or to changing any existing connections.
1
Connect microphones (balanced or unbalanced) to the XLR jacks MIC channel CH 1-6. For phantom
powered microphones switch on the phantom power (see section 5.4).
Caution! If the phantom power is switched on, no unbalanced microphones must be connected to the
corresponding inputs. Otherwise these microphones may be damaged.
2
Connect units with line level (e.g. CD players) to the RCA jacks LINE channel 1-8. Make sure that the
right/left occupation (plug color red/white) is the same at these units.
3
Connect PA amplifiers for speakers or subsequent units with line level to the unbalanced RCA jacks or
balanced XLR jacks OUT 1-6.
Balanced use with XLR connectors
2
1
1 = Ground / Shield
2 = Hot (+)
3 = Cold (-)
3
Input
For unbalanced use pin 1 and pin 3 have to be bridged
Fig. 1 Occupation of the XLR connectors

5.3 Connection with the mains

Connect the device to the mains with the supplied power supply cable. The occupation of the connection
cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
Attention! The earth has to be connected! If the device will be directly connected with the local power
supply network, a disconnection switch with a minimum opening of 3 mm at every pole has to
be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with
the IEC standards. The electric installation must be equipped with a Residual Current Device
(RCD) with a maximum fault current of 30 mA.
1
2
3
Output
International
L
N
17/19
00033027.DOC, Version 1.0