Herunterladen Diese Seite drucken

AKO -16523 Schnellstartanleitung Seite 14

Vorschau ausblenden Andere Handbücher für AKO-16523:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
Configuration
Condensed programming menu
Enables the rapid configuration of the most frequently-used parameters (SP, C1, d0, d1, d4, F3, A1 and A2).
Press the SET key for 3 seconds to access it.
Extended programming menu
Use the extended programming menu to configure all of the unit's parameters in order to adapt it to installation
requirements. Press the SET key for 6 seconds to access it.
IMPORTANT: If the function of the password has been configured as a keypad block (b10=2), or as
an access block to parameters (b10=1), you will be requested to enter the access code programmed in
PAS when attempting to access either of the two functions. If the entered password is not correct, the
unit will go back to showing the temperature.
IMPORTANT: Certain parameters or menus may not be visible depending on the configuration of the
rest of the parameters.
Regulation and control
Description
SP
Temperature setting (Set Point)
RE
C0
Probe 1 calibration (Offset)
C1
Probe 1 differential (Hysteresis)
C2
Set Point top locking (it cannot be set above this value)
C3
Set Point bottom locking (it cannot be set below this value)
Type of delay for the protection of the compressor:
C4
0=Minimum time of compressor in OFF
1=Minimum time of compressor in OFF and in ON in each cycle
C5
Protection delay time (Value of the option selected in parameter C4)
COOL relay status with fault in probe 1:
C6
0=OFF; 1=ON; 2=Average according to last 24h prior to probe error
3=ON-OFF according to prog. C7 and C8
Relay time in ON in the event of probe 1 failure
C7
(If C7=0 and C8¹0, the relay will always be disconnected in OFF)
Relay time in OFF in the event of probe 1 failure
C8
(If C8=0 and C7¹0, the relay will always be connected in ON)
C9
Maximum duration of the continuous cycle mode. (0=deactivated)
Variation of the Set Point (SP) in continuous cycle mode. When it reaches this
C10
point (SP+C10), it reverts to the normal mode. (SP+C10 ³ C3).
The value of this parameter is always negative, unless it is 0. (0=OFF)
Variation of the Set Point (SP) when the change Set Point function is active.
C12
(SP+C12£ C2) (0= deactivated)
Maximum start time from Pump Down
C19
(Values between 1 and 9 seconds will not be accepted) (0=deactivated)
C20
Maximum time for pump down (0= deactivated)
Values Min.
ºC/ºF
ºC/ºF
ºC/ºF
ºC/ºF
ºC/ºF
Min.
Min.
Min.
ºC/ºF
ºC/ºF
Min.
14
1652H311 Ed.02
Def. Max.
-50
0.0
99
-20.0
0.0
20.0
0.1
2.0
20.0
C3
99
99
-50
-50
C2
0
0
1
0
0
120
0
2
3
0
10
120
0
5
120
H.
0
0
48
0
-50
C3-SP
C3-SP
0.0
C2-SP
Sec.
0
0
120
0
0
15

Werbung

loading

Diese Anleitung auch für:

Ako-16520Ako-16523dAko-16523pAko-16520p