Off= Apartment building function disabled.
On= Apartment building function enabled.
DSW4
This enables or disables the pre-blinking function.
Off= Pre-blinking disabled.
On= Pre-blinking enabled.
DSW5
This enables or disables the motor starting function.
Off= Motor starting function disabled
On= Motor starting function enabled
DSW6
This selects the type of intervention of the "FTC" input on opening.
Off= No intervention
On= Temporary stop
DSW7
This selects the type of functioning of the "OPEN" input.
Off= Functioning as "OPEN button"
On= Functioning as "PEDESTRIAN button"
DSW8
Enables or disables braking.
Off= Electric braking disabled.
On= Electric braking enabled.
Dip-Switch "Bypass" Function
The Dip-Switches "Bypass" allow to short-circuit the normally closed inputs that are not in use.
DSW1
Input Stop
Off= Enabled input
On= Disabled input.
DSW2
Input FTC
Off= Enabled input
On= Disabled input.
DSW3
Input FCA
Off= Enabled input
On= Disabled input.
DSW4
Input FCC
Off= Enabled input
On= Disabled input.
This control unit performs the power circuit integrity test automatically. Should a fault be detected, the unit
stops and indicates the fault through the flashing of the power indicator strip.
The triggering of the thermal switch is considered a fault in the power circuit, and once the thermal protec-
tion is reset, the control unit restarts automatically.
If the control unit keeps on indicating a faulty operation, even when the motor has cooled down, try to
momentarily switch power off.
Trimmer functions
TCA
This allows the automatic re-closing time to be adjusted when this is enabled by positioning the
DSW2 Dip-switch on OFF.
Adjustment can be from a minimum of 1 to a maximum of 250 seconds.
Turn the trimmer completely clock-wise to adjust the minimum time.
TL
This allows the working time of the automation to be adjusted. If the limit switches fail, the soft-
ware protection will intervene after this time has elapsed. (Add about 4 sec. to the actual stroke
time of the automation).
Adjustment can be from a minimum of 1 to a maximum of 250 seconds.
Turn the trimmer completely clock-wise to adjust the minimum time.
Braking
In the last 7 seconds before the end of the working time (thus for about 3 seconds of actual
stroke if TL is preset at 4 seconds more than the stroke), the motor will slow down and complete
its stroke at 75% of the preset force.