AFTER USE
Empty the reservoir
DANGER! Hot water! Wait until the water has
cooled before completing this step.
To prevent the build-up of limescale and higher salt/mineral levels,
empty the reservoir after each bath. If this is not done and water
is added each time you take a sauna, foam build-up can occur
which can cause the level sensor to detect a higher water level
than actual, with a risk that the heater element will break.
To empty (see Figure 5):
1.
Remove the hatch.
2.
Pull out the hose.
Open the valve over a suitable container and drain off the
3.
remaining water.
Close the valve and put back the hose and hatch.
4.
3
Figure 5: Emptying the water reservoir (switch off the heater).
1
2
Switch off main power switch
CAUTION! The heater's memory function will be
cancelled if disconnected from the mains for more
than 7 days. The date and time will have to be repro-
grammed.
The main power switch is at the bottom of the heater.
Switch off here when the heater is not to be used for an extended
period (e.g. several weeks).
Note: Do not turn off the main switch while the sauna heater is
in operation and heating, except if shutdown is required due to a
fault or emergency.
1
OFF
Figure 6: Location of main power switch
MAINTENANCE
After each use
As required
Empty the water
Descale the water
reservoir.
reservoir.
Clean the herb
bowl and fragrance
holder..
Clean the electro-
des using a cloth or
similar. See fig. 7.
x2
Figure 7: Cleaning the electrodes. Switch off main power switch.
A. Red electrode: Water level sensor Mid
B. Black electrode: Water level sensor High
Note: The electrode pins must not have fat deposits
or other deposits on them. The electrode pins must
not touch each other or touch the interior walls of
the level pipe. This can cause an error code or im-
pact the water level.
ON
Once annually
Check the stone
compartment.
B
High
GND M H
A
Mid
9