6
Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The hot and cold supplies must be of equal
pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Handspray flow rate:
Aerator flow rate:
anti-pollution function
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
8 l/min
10 l/min
Assembly see page 32
Maintenance (see page 31)
The non return valves must be checked
regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
To adjust the hot water limiter on single lever
mixers, please see page 34. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Dimensions (see page 31)
Spare parts (see page 35)
Operation (see page 36)
Cleaning (see page 31) and
enclosed brochure
If the waterflow drops, clean the filter
located between hose and handspray.
Test certificate (see page 36)