Equipment Data - Dimplex Sih 40Te Montage- Und Gebrauchsanweisungen

Vorschau ausblenden Andere Handbücher für SIH 40TE:
Verfügbare Sprachen

Verfügbare Sprachen

12

12 Equipment Data

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529
2.2
Installation location
3
Performance data
3.1
Operating temperature limits:
1
Heating water flow
Brine (heat source)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow)
3.3
Heat output / COP
3.4
Sound power level
3.5
Sound pressure level at a distance of 1 m
3.6
Heating water flow with an internal pressure differential of m³/h / Pa
3.7
Brine throughput with an internal pressure differential
(heat source) of
3.8
Refrigerant; total filling weight
3.9
Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos M
5.4
5.5
max. power consumption of compressor protection
(per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. For brine temperatures between -5 °C and 0 °C, flow temperature increasing from 65 °C to 70 °C.
2. This data indicates the size and capacity of the system to EN 255 and EN 14511. For an analysis of the economic and energy efficiency of the system, both the bivalence point
and the regulation should also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water
flow temperature 55 °C.
3. Operation with 2 compressor
4. Operation with 1 compressors
5. Note that additional space is required for pipe connections, operation and maintenance.
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump controller must always be ready for operation.
E-8
°C
°C
at B0 / W35
K
2
at B-5 / W55
kW / ---
kW / ---
2
at B0 / W45
kW / ---
kW / ---
2
at B0 / W50
kW / ---
kW / ---
2
at B0 / W35
kW / ---
kW / ---
dB(A)
dB(A)
m³/h / Pa
type / kg
type / litres
5
H x W x L mm
Inch
Inch
kg
V / A
2
B0 W35
kW
A
3
A / ---
W
7
SIH 40TE
up to 70±2
-5 to +25
Monoethylene glycol
9.8
3
28.9 / 2.4
4
10.6 / 2.1
3
4
3
33.1 / 3.1
4
13.5 / 2.4
3
36.6 / 4.4
4
18.6 / 4.4
3.2 / 1100
11.0 / 11900
R134a / 8.0
Polyolester (POE) / 6.5
1890 x 1350 x 775
G 1 1/2'' internal/external
G 2 1/2'' internal/external
400 / 50
8.36
15.09 / 0.8
IP 21
Indoors
25%
5.0
31.7 / 3.2
12.9 / 2.5
34.2 / 4.1
17.4 / 4.1
65
50
5.5 / 2900
8.8 / 7800
502
8.35
84
15.06 / 0.8
65
6
Yes
2
Internal
loading