6

Disposal

CAUTION
Physical exertion / weight of the disposal tanks. Filled disposal tanks are very heavy.
Use suitable lifting and transport equipment.
A visual and acoustic signal is sounded on reaching a maximum level in the disposal tanks. Operation of the auger screw
and the skimmer is stopped after a remaining running time of 5 minutes. The corresponding drum must be replaced and
the sensor checked for soiling. Cleaning must be carried out if necessary. The functional capability of the system must be
checked after completion of the disposal process, see "Functional test", page 66.
Carry out disposal procedure for disposal tanks (once for the grease drum and once for the coarse materials drum):
Ensure that the auger screw and skimmer unit are not operating. (Operating LED on the respective control unit flashes
green).
Position an additional, emptied disposal tank.
Release the clamping ring on the disposal tank and take the cover off.
Set the empty disposal tank underneath.
Tighten clamping ring.
Check whether the coarse filter unit is ready for operation:
Check whether an alarm is present on the control unit.
Check whether there are grease or coarse material deposits at the emergency overflow, or whether there is waste-
water in the emergency overflow. If this is the case, the auger screw must be serviced.