Herunterladen Diese Seite drucken

Troubleshooting - Hendi 263501 Gebrauchsanweisung

Kontaktgrill
Vorschau ausblenden Andere Handbücher für 263501:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

H.

Troubleshooting

Troubles
1. Module plates are out of heating
when the power and heating indicator
are both on.
2. When the power is on and
temperature controller is switched
and heating indicator is on and
temperature can be not controlled.
3. Indicator is not on when the power
is on and the heating process is
normal.
The indicator is out of order when the
power is on.
Aforementioned troubles are just for reference. If any fault occurs, please cease using and turn to professional
technicians for check and repair.
I.
Circuit Diagram
~230V、50Hz
BROWN
L
SA
BLUE
N
GREEN-YELLOW
E
E
G H - 811 G H - 811B G H - 811C
263501 / 263600 / 263655
~230V、50Hz
BROWN
L
BLUE
N
GREEN-YELLOW
E
E
263709 / 263808 / 263907
HL1, HL3----POWER INDICAOTR
SA, SA1, SA2----TEMPERAUTRE CONTROLLER
TEMPERAUTRE CONTROLLER
EH1, EH2, EH3, EH4----HEATING WIRE
J.
Daily Check
Causes
1. Temperature controller is broken.
2. At least one of heating wires is
burned.
3. Temperature protector works.
1. Temperature controller is out of
order.
1. Indicator is broken.
1. Abnormal power supply or cut-off
power supply.
2. Fuse is burned.
SB
HL1
SB1
SA1
HL1
SB2
SA2
HL3
HL2, HL4----HEATING INDICATOR
E----GROUND CONNECTION
Solutions
1.
2.
3.
1. Change temperature controller.
1. Change temperature controller.
1. Check power supply and
2. Change fuse.
EH1
EH2
HL2
EH1
EH2
HL2
EH3
EH4
HL4
Change temperature controller.
Change the burned heating
tube.
Dismantle the bottom plate and
use hand to reset temperature
protector.
connection to make power supply
be normal.