Operation
Operation with water vapour cartridge
20.5.2

Expansion foam operation

Start expansion foam operation
Stop expansion foam operation
84 / 97
In combination with the following equipment, expansion foam can also
be produced.
Foam compound
Proportioner
Foam net
Air tube
Fold out stabiliser.
Release stabiliser lock.
Fold out stabiliser.
Close stabiliser lock again.
Connecting to a suitable water supply.
The water supply hoses can be laid to the high performance fan
from behind.
Max 5 bar water pressure and approx. 200 l flow rate.
Mount the foam net with integrated tension belt on the nozzle unit.
Mount the air tube over the foam net and fix it with a belt.
Shorten the tension belts to the required length, to prevent suction in
the nozzle unit.
Attach the tension belt ends to the handles or the frame of the high per-
formance fan to avoid suction.
Mount proportioner.
Mount on the connection coupling of the high performance fan.
Or
Mount between high performance fan and water supply.
Operate high performance fan.
Refer to chapter "Start high performance fan".
Expansion foam is discharged from the high performance fan.
With commercially available multi-range foaming agents, the following
foam expansion is achieved by the air performance.
1:500 to 1:800
Stop foam supply.
Stop high performance fan.
Refer to chapter "Stop high performance fan".
Expansion foam operation is stopped.
After each foam operation, all parts supplied with foam must be flushed.