Herunterladen Diese Seite drucken

Grohe ESSENCE E 36 444 Montageanleitung Seite 6

Vorschau ausblenden Andere Handbücher für ESSENCE E 36 444:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operation and settings,
see technical product information, 99.0438.xxx.
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes.
Maintenance
, see fold-out page III and IV.
• Shut off hot and cold water supply.
• Disconnect voltage supply.
• Inspect and clean all components and replace if
necessary.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
Undesired water
• Sensor system detection zone set too high
flow
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Filters in connection hose dirty
Automatic flush
• Safety shutdown active
does not work
• Ambient conditions not suitable
F
Consignes de sécurité
Éviter les dangers entraînés par une tension
d'alimentation endommagée. En cas
d'endommagement du câble d'alimentation, le faire
remplacer par le fabricant, son service après-vente
ou une personne disposant des mêmes qualifications
afin d'éviter tout risque de blessure.
• Ne procéder à l'installation que dans un endroit à l'abri du
gel.
• L'adaptateur secteur n'est approprié que pour l'usage dans
des pièces fermées.
• La fiche de raccordement ne doit pas être exposée aux
éclaboussures d'eau directes ou indirectes.
3
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
for local conditions
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
Replacement parts,
see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
accessory, prod. no.: 36 407) / app
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Remove object
- Check ambient conditions with remote control
(special accessory, order no.: 36 407) in test mode
at maximum range, LED must not light up.
• L'alimentation électrique doit disposer d'un interrupteur
séparé.
• N'utiliser que des pièces de rechange et des accessoires
d'origine. L'utilisation d'autres pièces entraîne
automatiquement l'annulation de la garantie et du label CE,
ainsi qu'un risque de blessures.
Caractéristiques techniques
Robinetterie avec convertisseur:
• Tension d'alimentation : 100-240 V CA 50-60 Hz/6,75 V CC
• Puissance :
Robinetterie avec pile:
• Tension d'alimentation :
2,4 W
pile lithium 6 V de type CR-P2