Interconnecting several devices (master/slave operation)
Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
1
Configure all slave units before connecting the master unit: Set each Slave device to the same DMX
address "001".
2
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
3
Set the master unit to the desired operating mode, either Dimmer or Strobe. The interconnected devices
will now operate synchronously.
Focus
Step 1: Loosen the focus fixation screws on both sides of the device.
Step 2: Adjust the focus by sliding the lens-housing forward or backward.
Step 3: Tighten the focus fixation screws on both sides of the device.
Zoom
Step 1: Loosen the zoom fixation screws on both sides of the device.
Step 2: Adjust the zoom by sliding the lens-housing forward or backward.
Step 3: Tighten the zoom fixation screws on both sides of the device.
Please note: When setting the focus or zoom, always adjust on both sides of the unit. One-sided adjusting
could lead to a misalignment in the guide grooves.