7. TO DEFLATE
1. Remove the cover on the deflation port by unscrewing the appropriate knobs (point 3 - fig 1)
2. Connect the inflation hose to the IN input port of the inflator (point 3 - fig 1)
3. Connect the other end of the hose to the valve of the inflatable.
4. Connect the inflator to the power supply via the power cord (point 4 - fig 1)
5. To start deflation press the ON/OFF switch (Point 1 Fig.1).
6. Switch off the inflator once deflation is complete.
WARNING
THE INFLATOR DOES NOT SWITCH OFF AUTOMATICALLY. SWITCH OFF THE INFLATOR ONCE THE DESIRED PRESSURE HAS
BEEN REACHED.
WARNING
IN THE EVENT OF A POWER FAILURE DURING OPERATION, THE DEVICE IS NOT ABLE TO KEEP THE WORKING SETTINGS
STORED AND CANNOT RESTART AUTOMATICALLY WHEN POWER IS RESTORED.
8. TROUBLESHOOTING
PROBLEM
The inflator does
not start
The inflator is
stopped
8.1 ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.
10
POSSIBLE CAUSE
The power cable is not connected to
the socket
The main GREEN switch is off
The power cable is damaged
The power cable is not
connected to the socket
The main switch is off
Over-temperature
POSSIBLE SOLUTION
Connect it correctly
Press the switch
Ask the SCOPREGA service to replace
or repair the cable
Connect it correctly
Press the switch
Wait until the ARS motors cool down.
The inflator will restart automatically.