Herunterladen Diese Seite drucken

Leuze electronic IPS 258i Bedienungsanleitung Seite 16

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
NOTICE
Protective Extra Low Voltage (PELV)!
The device is designed in accordance with protection class III for
supply with PELV (Protective Extra-Low Voltage).
Pin assignment
3
PWR / SWIO, M12 connector, A-coded
Pin No.
Designation
1
VIN
2
GND
3
SWI1
4
SWO2
5
FE
6
n.c.
7
SWO5
8
SWO6
9
SWO7
10
SWO8
11
SWI3
12
SWI4
Thread
FE (functional earth)
(M12
connector)
NOTICE
The core colors only apply if Leuze's original connection cables are
used (see operating instructions, chapter "Cables accessories").
16
Core color
Assignment (default)
Brown
+18 ... +30 V DC operating voltage
Blue
Negative operating voltage (0 V DC)
White
Digital switching input 1
(trigger)
Green
Digital switching output 2
(READY)
Pink
Functional earth
Yellow
Not assigned
Black
Digital switching output (-X)
Gray
Digital switching output (+X)
Red
Digital switching output (-Y)
Violet
Digital switching output (+Y)
Gray/pink
Digital switching input 3
(program selection 0)
Red/blue
Digital switching input 4
(program selection 1)
Connection cable shield.
The shield of the connection cable is
on the thread of the M12 connector.

Werbung

loading

Diese Anleitung auch für:

Ips 248iIps 208iIps 408iIps 448iIps 458i