Overview
1
A
Lens
B
Control panel with indicator LEDs, control buttons and program display
C
LEDs for illumination (infrared)
D
M4 mounting thread
E
Device housing
F
Housing hood
G
M12 connection technology
H
Feedback LED (4x green, +X -X +Y -Y)
Part number code
IPS axxiC FIX-f -102-Ir-Z-A
IPS
Operating principle: Imaging Positioning Sensor
a
Series:
– 2: IPS 200i
– 4: IPS 400i
xx
Host interface
– 08: Ethernet TCP/IP, UDP
– 48: Ethernet TCP/IP, UDP, PROFINET
– 58: Ethernet TCP/IP, UDP, EtherNet/IP
i
Integrated fieldbus technology
C
Open Platform Communication - Unified Architecture (OPC-UA)
– -: without OPC-UA functionality
– C: OPC-UA functionality
FIXED
Fixed focal length
f
Optics model:
– M3: Medium Density (4.3 mm lens)
– F2: Far Density (12 mm lens)
– F4: Far Density (16 mm lens)
102
Device with connector/socket
Beam exit at front
I
Illumination: infrared
r
Resolution range:
– 3: 1280 x 960 pixels
Z
Type of protective screen:
– -: Plastic
– G: Glass