1
Publishing Notes ........................................................ 9
2
Explanation of Symbols ............................................. 9
3
Tools and Aids required ............................................. 9
4
Description ................................................................ 9
5
Notes before Assembly .............................................. 9
6
Mounting HSI90, HSI150 S_° .................................... 9
7
wall insert)............................................................... 10
8
9
FHRK-Quality Seal .................................................... 11

1 Publishing Notes

Copyright © 2023 by
Hauff-Technik GmbH & Co. KG
Department: Technical Editing
Robert-Bosch-Straße 9
89568 Hermaringen, GERMANY
Tel.
+49 7322 1333-0
Fax
+49 7322 1333-999
E-mail
office@hauff-technik.de
Internet
www.hauff-technik.de
Reproduction of this Installation instructions - even in ex-
tracts - in the form of reprint, photocopy, on electronic
data media or using any other method requires our writ-
ten consent.
All rights reserved.
Subject to technical alterations at any time and without
prior announcement.
These installation instructions form part of the product.
Printed in the Federal Republic of Germany.

2 Explanation of Symbols

1
Work stages
► Effect/result of a work step
Reference numerals in drawings

3 Tools and Aids required

For the correct installation of the slanted wall in-
sert HSI90/HSI150 the following tools and aids are re-
quired in addition to the usual standard tools:
Tools:
1
flexible socket spanner SLS 6G (Hauff)
2
flexible socket spanner SLS 6GD (for walls with pe-
rimeter insulation)
3
bolt cutter
Art. Nr.: 5090020175 Rev.: 03/2023-07-14
Aids:
KRMTX cable cleaner (Hauff)
Cleaning cloth

4 Description

Example slanted double wall insert HSI150 1xz K2 S_°/X
(see Fig.: 1)
Legend for Fig.: 1
1
Polystyrene wedge
2
Attachment frame
3
HSI150 K2
4
Nail holes for formwork fastening

5 Notes before Assembly

NOTICE
Lack of minimum concrete covering according to the wa-
terproof concrete directive (information sheet H10)!
If the minimum concrete covering is < 200 mm, the water-
proof concrete directive has not been observed.
Single and double slanted wall inserts do not meet
the minimum concrete wall thickness of 200 mm ac-
cording to the waterproof concrete directive; this is
only the case form the following wall thicknesses:
Typ
HSI90 S30°
HSI90 S45°
HSI90 S60°
HSI150 S30°
HSI150 S45°
HSI150 S60°
As a general rule, slanted wall inserts are not suit-
able for modular construction! in this case, cus-
tomised solutions may be necessary for the con-
creting stages at the precast plant.
6 Mounting HSI90, HSI150 S_°
Observe installation position and alignment ac-
cording to planning!
• The minimum clearance of ≥ 10 cm between
the slanted wall inserts must be observed (see
Fig.: 2).
• A gap of at least 5 cm is to be observed be-
tween three-ribbed seals and iron rein-force-
ments. The tie wire may not be attached to
the three-ribbed seals.
Legend for Fig.: 2
1
Formwork outside of building
2
Minumum clearance ≥ 10 cm
3
Angle S[°]
EN
wall thickness
298 mm
335 mm
360 mm
342 mm
385 mm
420 mm