Herunterladen Inhalt Inhalt Diese Seite drucken

WIKA 333.30.160 Betriebsanleitung Seite 16

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Commissioning, operation
Depending on the application, fill the device with the medium
before screwing it in, in order to ensure it functions properly.
Mounting is only permitted in the depressurised state. Reliably
EN
depressurise the instrument using the available valves and protec-
tive devices (e.g. shut-off valve, monoflange).
Nominal position per EN 837-3 / 9.6.6 image 7: 90°±5° ( ⊥ ), if not
stated otherwise in the order documentation.
With parallel male threads (e.g. G ½ B), use flat gaskets, lens-type
sealing rings or WIKA profile sealings.
With tapered threads (e.g. NPT threads), the sealing is made in
the thread, using suitable sealing material (EN 837-2).
When screwing the instruments in, the force required for sealing
must not be applied through the case, but only through the
spanner flats provided for this purpose, and using a suitable tool.
The tightening torque is dependent on the selected process
connection.
16
Spanner flats
Sealing face
WIKA operating instructions, test gauge model 3
Sealing in the thread
Installation with open-ended spanner

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis