Herunterladen Inhalt Inhalt Diese Seite drucken

Disposal - Dometic HIPRO A30 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HIPRO A30:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
Dometic HiPro Apollo, Evolution
Problem
Minibar is not cooling. Indicator LED is
continuously flashing.
Poor cooling performance
Frost formation in the minibar com-
partment
Interior lighting is not working

10 Disposal

WARNING! Fire hazard
• The refrigerant is highly flammable. Do not open or damage the refrigerant circuit.
• The insulation of the device contains an insulating gas (see data plate). Do not damage the insula-
tion.
Possible cause
Minibar is in silent mode.
Cooling unit is blocked.
Cooling unit is not water-tight.
Heating element is defective.
Error during self-test
Cooling unit is not sufficiently ventilat-
ed.
Minibar is exposed to direct sunlight.
Door of minibar is not closed with a
tight seal.
Minibar recently filled.
For versions with absorber cool-
ing: The input voltage is too low or
too high.
Door of minibar is not closed with a
tight seal.
Power plug is not plugged in.
Interior lighting is defective.
Surface of infrared door sensor is cov-
ered by condensation.
Suggested remedy
Service agent only: Replace
the minibar.
No action required
(Setting the silent
mode (only for
C40)).
Contact an authorized service agent.
Provide sufficient ventilation (see Instal-
lation Manual).
Remove the minibar out of direct sun-
light.
Check distances (see Installation Man-
ual).
Contact an authorized service
agent.
Service agent only: Replace
door seal
Check cooling again after 5 h ... 6 h.
Check input voltage.
Check distances (see Installation Man-
ual).
Contact an authorized service
agent.
Service agent only: Replace
door seal
Insert the power plug into the socket.
Contact an authorized service
agent.
Service agent only: Change
interior lighting
Clean the surface of the infrared door
sensor.
EN